Data Communication Cables
Communication Cables
Communication Cables are generally known as Low Voltage Cables for control, signal and data transmission. They are halogen-free, preventing corrosive gasses and smoke in the event of a fire. These cables are suitable for hospitals, airports, hotels, theatres, schools, data installations, and crowded commercial spaces.
Control & Signal Cables
Network (LAN) CABLES
Control & Signal Cables
Flexible Control & Signal Cables
We have a wide range of environment friendly products while maintaining quality aimed at customer satisfaction. We import control and signal cables for industrial and commercial sectors, commonly for computer systems, electronic control, office equipment, scales, and measuring devices. They are not recommended for use in open air, but can be used in places where electromagnetic interference exists because the braiding reduces the electromagnetic influence.Cable structure
- Conductor: Plain copper wire stranded IEC 60228, VDE 0295 / class 5
- 0.22-0.34 mm2: Tinned copper wire 7-strand
- Insulatıon: HFFR (LSZH) compound – TS EN 50290-2-26
- Insulatıon colours: Acc. to DIN 47100
- Above 10 cores: White or Black cores (numbered)
- Stranding: Cores stranded in layers, PES tape wrapped
- Braiding: Tinned copper wire braiding (coverage %50)
- Outer sheath: HFFR (LSZH) compound – TS EN 50290-2-27
- Outer sheath colour: Grey RAL7032
Technical data (20ºC)
- Operating temperature: – Flex: -5° / +70 °C- Fixed: -30° / +70 °C
- Bending Radius: 10 x D
- Rated Voltage: 300/500 V
- Test voltage: < 1.0 mm2 – 1.2 kV AC 1 min. > 1,0 mm2 – 2,5 kV AC 1 min.
- Insulation resistance: min. 200 MΩ.km
- Flame retardance: IEC 60332-1-2
- Amount of halogen acid gas: IEC/EN 60754-1, EN 50267-1, BS EN 50267-1, DIN VDE 0482-267-1
- Degree of acidity of gases: IEC/EN 60754-2, EN 50267-2, BS EN 50267-2, DIN VDE 267-2-2
- Smoke density test: IEC/EN/BS 61034-1/2, DIN VDE 0482-1034-½
Flexible Screened Twisted Pair Cables
These Data and Signal cables are used in computer systems, electronic control and office equipment, scales, measuring devices. They are not recommended for use in the open air, but can be used in places where electromagnetic interference exists because the braiding reduces the effects of electromagnetic influences. Due to the paired construction, cross talk is reduced between the signal pairs.Cable structure
- Conductor: Plain copper wire stranded IEC 60228, VDE 0295 / class 5
- 0,22-0,34 mm2: Tinned copper wire 7-wire
- Insulatıon: HFFR (LSZH) compound – TS EN 50290-2-26
- Insulatıon colours: Acc. to DIN 47100
- Above 5 pairs: White – Blue (each numbered)
- Pairing: Cores twisted to form a pairs
- Stranding: Pairs stranded in layers, PES tape wrapped
- Braiding: Tinned copper wire braiding (coverage %50)
- Outer sheath: HFFR (LSZH) compound – TS EN 50290-2-27
- Outer sheath colour: Grey RAL7032
Technical data (20ºC)
- Operating temperature– Flex: -5° / +70 °C– Fixed: -30° / +70 °C
- Bending Radius: 10 x D
- Rated Voltage: 300/500 V
- Test voltage: < 1,0 mm2 – 1,2 kV AC 1 min. > 1,0 mm2 – 2,5 kV AC 1 min.
- Insulation resistance: min. 200 MΩ.km
Network (LAN) CABLES
Cat 5e S-FTP
These indoor and outdoor cables are produced according to EIA/TIA 568 standard to ensure high performance up to 155 MHz. The varying and very short lay lengths of pairs guarantee a high crosstalk attenuation value. Screening protects the cable against electromagnetic interference.Cable structure
- Conductor: Bare copper solid wire 0.51 mm (24 awg)
- Insulatıon: PE (2Y) compound
- Core identification: EIA/TIA 568
- Core Colours: – Blue – white/blue stripe – Orange – white/orange stripe – Green – white/green stripe – Brown – white/brown stripe
- Pairing: Cores twisted to form pairs with different lay lengths
- Stranding: Pairs stranded together, PES tape wrapped
- Screening overall: Aluminium Foil +0.50 mm Tinned copper drain wire+Tinned copper wire braiding (coverage %50-55)
- Outer sheath: PE (2Y) compound / Black (or on request)
Technical data (20oC)
- Rated Voltage: 250 V
- Test voltage: 1.0 kV AC 1 min.
- Insulation resistance: min. 1000 MΩ.km
- Temperature range: -5° /+60°C
- Bending Radius: 7.5xD
- Capacitance (1 kHz): nom. 56.0 nF/km
- Impedance (1 MHz): 100±%15 Ω
- Attenuation: 22.0 dB (100 MHz)
- NEXT min.: 35.0 dB (100 MHz)
- Return Loss min.: 20.0 dB (100 MHz)
- Halogen amount/acidity tests: TS EN 50267-2
- Smoke density test: TS EN 61034-2
Cat 6A S-FTP
These indoor cables are produced according to EIA/TIA 568 standard to ensure high performance up to 250 MHz. The varying and very short lay lengths of pairs guarantee a high crosstalk attenuation value. Screening protects the cable against electromagnetic interference.Cable Structure
- Conductor: Electroliytic solid copper conductor(Awg 23)
- Insulatıon: Foam/skin polyethylene compound
- Screen: Aluminium/pet tape
- Stranding: Screened 4 pairs of common twist
- Screen: Tinned copper drain wire;Tinned copper braid
- Outer sheath: EN 50290-2-27 Lszh compound
- Outer sheath colour: Ral 7035 Grey; Ral 2003 Orange (other colours on reguest)
Technical characteristics
- Tensile strength: max. 110 N
- Crushing strength: min. 1000 N/10 cm
- Resistance imbalance: max %2
- Insulation resistance: min 5000 MΩx m
- Capacitance: nom. 42 pF/m
- Capacity imbalance: max. 1600 pF/km
- Operating voltage: 72V
- Test voltage: 1000V
- Conductor resistance: max.75 Ω/km
- Characteristic impedance: 100 + 5 Ω @100MHz
- Bending radius: fixed min. 4 x D flexing min. 8 x D
- Temperature range: fixed -20°C …+60°C flexing 0°C …+50°C
- Impact resistance: min. 10 Impact
- Velocity of propagation: 78-80%
- Propagation delay: max.430 ns/100m
- Signal delay: max.25 ns/100m
Looking for Data Communication Cables? Contact TEK Electrical Cables Trading LLC!