HF Coaxial Cables
HF Coaxial Cables
50 Ohms RG Coaxial Cables
50 Ohms RG Halogen-Free Coaxial Cables have flame retardant characteristics by design and are used in densely populated places such as shopping centres, hotels, or ships. These Coaxial Cables do not emit dangerous smoke or corrosive gases in case there’s a fire. They have silver-plated conductors to ensure transmission with minimum losses.
50 Ohms RG Coaxial Cables are used in Radio transmitter applications, Ethernet networks, electronic laboratory interconnections, radio receiver connections and high-frequency digital applications.
All RG Coaxial cables are according to American Military Specification MIL-C-17.
Cable Structure
- Inner Conductor: 19×0.18 ±0.01 mm Tinned stranded copper wire
- Insulatıon: 2.95 ± 0.13 mm PE – Solid Polyethylene
- Shielding: Tinned copper wire braiding (coverage %85)
- Outer sheath: HFFR (LSZH) compound
- Outer sheath colour: Black /Siyah
- Outer sheath diameter: 5.0±0.20 mm
Technical Data (20°C)
- Temperature range: -20°C/+70°C
- Impedance: 50 ± 3 Ω
- Insulation Resistance min.: 10,000 MW.km
- Velocity Ratio: 66%
- Capacitance: 101.0 pF/m
- Test Voltage: 2.0 kV AC 1 min.
- Frequency(MHz) 100 200 400 600 800 1000Attenuation 17 24 38 46 53 64
- Flame retardance: IEC 60332-1, VDE 0482-332-1-2, BS EN 60332-1-2
- Amount of halogen acid gas: IEC/EN 60754-1, EN 50267-1, BS EN 50267-1, DIN VDE 0482-267-1
- Degree of acidity of gases: IEC/EN 60754-2, EN 50267-2, BS EN 50267-2, DIN VDE 267-2-2
- Smoke density test: IEC/EN/BS 61034-1/2, DIN VDE 0482-1034-1/2
Construction
- Conductor: 7×0.76 mm Plain copper wire stranded
- Insulatıon: 7.25±0.25 mm Solid PE
- Screening: Plain copper wire braiding/ 0.15 mm (Coverage nom. %96)
- Outer sheath: LSZH (HFFR) compound
- Outer diameter: 10.30 ±0.15 mm
- Outer sheath colour: Black
Technical data (20ºC)
- Temperature range: -20°C/+70°C
- Test voltage: 5.0 kV AC
- Impedance: 50 ± 2 Ω DC
- Resistance inner conductor: nom. 5.7 Ω/km DC
- Resistance outer conductor: nom. 3.9 Ω/km
- Insulation resistance min.: 10,000 MΩ.km
- Capacitance: nom. 101 pF/m
- Velocity Ratio: 0.66
- Frequency (MHz) 100 200 400 600 800 1000Attenuation 7.2 11.0 16.5 21.0 24.0 30.0max. (dB/100 m)
- Flame retardance: IEC 60332-1, VDE 0482-332-1-2, BS EN 60332-1-2
- Amount of halogen acid gas: IEC/EN 60754-1, EN 50267-1, BS EN 50267-1, DIN VDE 0482-267-1
- Degree of acidity of gases: IEC/EN 60754-2, EN 50267-2, BS EN 50267-2, DIN VDE 267-2-2
- Smoke density test: IEC/EN/BS 61034-1/2, DIN VDE 0482-1034-½
Construction
- Conductor: 0.90 ±0.02 mm Silver plated copper wire solid
- Insulatıon: 2.95 ±0.15 mm Solid PE – Screening: Silver plated copper wire braiding / 0.12 mm (coverage min. %85) – Screening: Silver plated copper wire braiding / 0.12 mm (coverage min. %85)
- Outer sheath: LSZH (HFFR) compound
- Outer diameter: 5.40 ±0.20 mm
- Outer sheath colour: Black
Technical data (20ºC)
- Temperature range: -20°C/+70°C
- Test voltage: 2.5 kV AC max.
- Operating Voltage: 1.90 kV AC
- Impedance: 50 ± 3 Ω
- Insulation resistance: min. 10,000 MΩ.km
- Capacitance: nom. 101 pF/m
- Velocity Ratio: 0.66
- Frequency (MHz) 50 100 200 400 600 800 1000Attenuation nom. 9.8 13.2 21.0 32.0 36.0 44.0 50.0(dB/100 m)
- Flame Retardance: IEC 60332-1, VDE 0482-332-1-2, BS EN 60332-1-2
- Amount of halogen acid gas: IEC 60754-1, EN 50267-1
- Degree of acidity of gases: IEC 60754-2, EN 50267-2
- Smoke density test: IEC 61034-1, VDE 0482-1034-1/2
Construction
- Conductor: 7×0.76 mm Silver plated copper wire stranded
- Insulatıon: 7.25±0.25 mm Solid PE – Screening: Silver plated copper wire braiding /0.12 mm (coverage nom.%94) – Screening: Silver plated copper wire braiding/0.12 mm (coverage nom.%97)
- Outer sheath: LSZH (HFFR) compound
- Outer sheath diameter: 10.80 ±0.20 mm
- Outer sheath colour: Black
Technical data (20ºC)
- Temperature range: -20°C/+70°C
- Test voltage: 5.0 kV AC
- Impedance: 50 ± 2 Ω
- DC Resistance inner conductor: nom. 5.7 Ω/km
- DC Resistance 1.outer conductor: nom. 6.2 Ω/km
- DC Resistance 2.outer conductor: nom. 6.2 Ω/km
- Insulation resistance: min. 10,000 MΩ.km
- Capacitance: nom. 101 pF/m
- Velocity Ratio: 0.66
- Frequency (MHz) 100 200 400 600 800 1000Attenuation 7.0 10.5 14.0 18.0 23.0 28.0max. (dB/100 m)
- Amount of halogen acid gas: IEC/EN 60754-1, EN 50267-1, BS EN 50267-1, DIN VDE 0482-267-1
- Degree of acidity of gases: IEC/EN 60754-2, EN 50267-2, BS EN 50267-2, DIN VDE 267-2-2
- Smoke density test: IEC/EN/BS 61034-1/2, DIN VDE 0482-1034-1/2
75 Ohms Halogen-Free RG Coaxial Cables
75 Ohms Halogen-Free Coaxial Cables have flame retardant characteristics by design and are used in densely populated places such as shopping centres, hotels, or ships. These Coaxial Cables do not emit dangerous smoke or corrosive gases in case there’s a fire.
75 Ohms RG Coaxial Cables are used as a distribution and connection cable for indoor CATV, CCTV systems where low attenuation is required.
All RG Coaxial cables are according to American Military Specification MIL-C-17.
Construction
- Conductor: 1.02±0.02 mm Cu Plain copper wire
- Insulatıon: 4.60±0.30 mm Physical Foam PE – Screening: Copper Foil – Screening: Plain Copper wire braiding
- Outer sheath: HFFR (LSZH) compound
- Outer diameter: 6.80±0.20 mm
- Outer sheath colour: Black/Green stripe
Technical data (20ºC)
- Temperature range: -20°C/+70°C
- Operating Voltage: 1.3 kV
- Test voltage: 1.5 kV AC 1 min.
- Impedance: 75 ± 3 Ω
- Insulation resistance: min. 10000 MΩ.km
- Capacitance: nom. 53 pF/m
- Velocity Ratio: 0.82
- Bending Radius: 20xD
- Frequency (MHz) 100 200 400 800 1000 2150 3000Attenuation 6.8 9.3 13.7 19.1 22.0 32.5 39.3 max. (dB/100 m)
- Flame retardance: IEC 60332-1, VDE 0482-332-1-2, BS EN 60332-1-2
- Amount of halogen acid gas: IEC/EN 60754-1, EN 50267-1, BS EN 50267-1, DIN VDE 0482-267-1
- Degree of acidity of gases: IEC/EN 60754-2, EN 50267-2, BS EN 50267-2, DIN VDE 267-2-2
- Smoke density test: IEC/EN/BS 61034-1/2, DIN VDE 0482-1034-½
Construction
- Conductor: 1.62±0.02 mm Cu
- Insulatıon: 7.20 ± 0.30 mm
- Physical Foam PE – Screening: Copper Foil – Screening: Plain Copper wire braiding
- Outer sheath: LSZH (HFFR) compound
- Outer diameter: 10.0±0.30 mm
- Outer sheath colour: Black
Technical data (20ºC)
- Temperature range: -20°C/+70°C
- Operating Voltage: 1.3 kV
- Test voltage: 1.5 kV AC 1 min.
- Impedance: 75 ± 3 Ω
- Insulation resistance min.: 10,000 MΩ.km
- Capacitance: nom. 53 pF/m
- Velocity Ratio: 0.82
- Bending Radius: 20xD
- Frequency (MHz) 5.0 200 400 800 1000 3000Attenuation 1.8 6.7 9.5 13.5 15.3 29.9max. (dB/100 m)
- Flame retardance: IEC 60332-1, VDE 0482-332-1-2, BS EN 60332-1-2
- Amount of halogen acid gas: IEC/EN 60754-1, EN 50267-1, BS EN 50267-1, DIN VDE 0482-267-1
- Degree of acidity of gases: IEC/EN 60754-2, EN 50267-2, BS EN 50267-2, DIN VDE 267-2-2
- Smoke density test: IEC/EN/BS 61034-1/2, DIN VDE 0482-1034-1/2
Construction
- Conductor: 0.81 ±0.02 mm Bare solid copper wire
- Insulatıon: 3.70 ± 0.20 mm
- Physical Foam Polyethylene PE – Screening: Copper Foil – Screening: Plain Copper wire braiding – 0.10 mm (Coverage min. 45% )
- Outer sheath: LSZH (HFFR) compound – TS EN 50290-2-22
- Outer sheath colour: White
- Outer diameter: 5.80±0.20 mm
Technical Data (20°C)
- Temperature range: -30°C/+70°C
- Operating Voltage: 1.1 kV
- Test voltage: 1.5 kV AC 1 min.
- Impedance: 75 ± 3 Ω
- Insulation resistance: min. 10,000 MΩ.km
- Capacitance: nom. 53 pF/m
- Velocity Ratio: 0.82
- Bending Radius: 15xD
- Frequency (MHz) 100 200 400 600 800 1000Attenuation max. 8.1 12.3 17.2 23.0 24.3 28.1max. (dB/100 m)
- Flame retardance: IEC 60332-1-2
- Degree of acidity of gases: IEC 60754-2, EN 50267-2
- Smoke density test: IEC 61034-1
Low Loss HF RG Coaxial Cables
Low Loss RG Coaxial Cables have flame retardant characteristics by design and are used in densely populated places such as shopping centres, hotels, or ships. These Coaxial Cables do not emit dangerous smoke or corrosive gases in case there’s a fire.
These cables are used in Radio transmitter applications, Ethernet networks, electronic laboratory interconnections, radio receiver connections and high-frequency digital applications.
These cables have a Copper conductor and Tinned copper braiding. They are halogen-free as per American Military Specification MIL- C17. They are used as connection cables in wireless and data transmission systems.
Construction
- Conductor: 2.74 ±0.02 mm Bare solid copper wire
- Insulatıon: 7.25 ± 0.25 mm FPE – Foam Polyethylene – Shielding: Aluminium Foil – Shielding: Tinned copper wire braiding (Coverage %85)
- Outer sheath: HFFR (LSZH) compound
- Outer sheath colour: Black
- Outer sheath diameter: 10.30 ±0.30 mm
Technical Data (20°C)
- max. Operating Voltage: 600 V AC
- Impedance: 50 ± 3 Ω
- Insulation resistance: min. 10,000 MΩ.km
- Capacitance: nom. 87 pF/m
- Velocity Ratio: 0.78 Test
- Voltage: 2.0 kV AC
- Inner conductor: DC
- Resistance: nom. 3.10 Ω/km
- Outer conductor: DC
- Resistance: nom. 5.90 Ω/km
- Frequency (MHz) 100 200 400 800 1000Attenuation 4.7 6.5 9.2 13.5 16.5 max. (dB/100 m)
- Flame retardance: IEC 60332-1, VDE 0482-332-1-2, BS EN 60332-1-2
- Amount of halogen acid gas: IEC/EN 60754-1, EN 50267-1, BS EN 50267-1, DIN VDE 0482-267-1
- Degree of acidity of gases: IEC/EN 60754-2, EN 50267-2, BS EN 50267-2, DIN VDE 267-2-2
- Smoke density test: IEC/EN/BS 61034-1/2, DIN VDE 0482-1034-1/2
Looking for HF Coaxial Cables Cables? Contact TEK Electrical Cables Trading LLC!
Our representatives are here to help you with your needs!